ROOM THERMOSTATS
Code | Description |
---|---|
TRMPEL | Electronic wall mounted room thermostat |
ROOM THERMOSTATS ON/OFF
Code | Description |
---|---|
TRMPOF | ON/OFF wall mounted room thermostat |
CRONO ROOM THERMOSTATS
Code | Description |
---|---|
TRMPTC | Crono touch-slide wall mounted room thermostat |
M-Bus Master
Code | Product's Description |
---|---|
MBUSLC1 | Level converter |
M-Bus level converter for managing up to 60 devices. Stand-alone field device for data collection from M-Bus meter to PC by using a USB connection. The M-Bus slave interface can be used as repeater in order to extend the M-Bus network up to additional 60 devices. 24 V ac/dc power supply, max. power consumption 7W.
RTU M-Bus
Code | Product's Description |
---|---|
MBWRTU1T | RTU M-Bus, 20 devices |
RTU M-Bus for managing up to 20 devices with datalogger function. Stand-alone field device for data collection from M-Bus meter by using a WEB interface. Integrated display for setup and data reading. It can be extended up to 250 devices by adding Level converter MBUSLC1. Pre-set for the M-Bus WIRELESS reading. 24 V ac/dc power supply, max. power consumption 7,5 W.
Datalogger
Code | Product's Description |
---|---|
MBUSRTU1 | RTU Datalogger |
RTU Datalogger for data collection and storage by using a WEB interface, which allows reading of the meters, report generation and remote consultation of old readings. Integrated display for setup and data reading. It can manage up to 250 M-Bus devices. 24 V ac/dc power supply, max. power consumption 3 W.
Note: to be coupled with Level Converter MBUSLC1
ENERGY METERS FOR HEATING PLANTS
Code | DN | Qp | Type |
---|---|---|---|
CMF00135B | 25 | 3,5 m³/h | Hot/Cold |
CMF01146B | 32 | 6 m³/h | Hot/Cold |
CMF11210B | 40 | 10 m³/h | Hot/Cold |
CONTER S
Product Type | Model |
---|---|
Hydraulic interface unit with heating/cooling lines and domestic hot and cold water | Conter S |
COMPONENTS | |
Strainer | |
Manual interception valves | |
Sintesi actuator 230V AC ON/OFF 1 microswitch / Sintesi actuator 24V AC ON/OFF 1 microswitch | |
1 heat meter and 2 DCW and DHW meters, M-Bus / 1 energy meter (heating/cooling) and 2 DCW and DHW meters, M-Bus | |
Frame and door | Optional |
Energy line insulation | Optional |
Flow rate control with balancing valve | Optional |
System start-up and technical support | Optional |
Direct energy metering
Centralised heating plant management
Centralised DHW production
Hot and cold sanitary water lines
Build-into-wall installation
CONTER
Product Type | Model |
---|---|
Configurable hydraulic interface unit with heating/cooling line | Conter |
COMPONENTS | |
Strainer | |
2-way or by-pass body valve | |
Inlet manual interception valves | |
Sintesi 230V actuator * / Sintesi 24V actuator / Sintesi 230V actuator with safety electronics | |
Mechanical energy meter, M-Bus / Mechanical energy meter (heating/cooling) M-Bus | |
Energy line insulation | Optional |
Flow rate control with static flow meter / Flow rate control with static balancing valve / Flow rate control with dynamic balancing valve / Flow rate control with ERP pump | Optional |
Low temperature (LT) plant with Sintesi 230V actuator and electronics | Optional |
Outlet manual interception valves | Optional |
DHW-DCW additional set for water line with stub piece / DHW additional set for 1 water line with stub piece / DCW additional set for 1 water line with stub piece | Optional |
DCW meter with pulse outputs / DHW meter with pulse outputs | Optional |
Small metal sheet box (for basic models) / Big metal sheet box (for models with flow regulation and manual interception valves or LT option) / Square shaped metal sheet box | Optional |
Small door and frame for QSA (for basic models) / Big door and frame for QSB (for models with flow regulation and manual interception valves or LT option) / Square shaped door and frame for QSC | Optional |
System start-up and technical support | Optional |
* Warning: the 230V motorised valve must be combined with a suitable electrical safety system according to law, such as our optional CGQKHT |
Direct energy metering
Centralised heating plant management
Centralised DHW production
Optional hot and cold sanitary water lines
Build-into-wall installation
Level Coverter M-Bus
Code | Description |
---|---|
MBUSLC250 | Level converter, 250 devices |
Level Converter M-Bus for the management of up to 250 devices. Stand-alone field module for M-Bus counter data reading through RS232, RS485 (exclusive) ports, M-Bus slave interface to be used as a repeater station and add another 250 devices to the M-Bus network. 230V AC power supply (power supply included).
Smart gateway
Code | Description |
---|---|
MBWSG | Wireless Smart Gateway M-Bus 200 devices - weekly transmission |
Data concentrator for the acquisition of RF device signals according to the M-Bus WIRELESS 868Mhz standard. It can cover a distance of 250 meters outdoors and 25 meters indoors. Configurable with Global Hub, IoT Platform. Built-in GPRS modem. It can manage up to 200 devices with weekly transmission (different intervals upon request). It supports the WIRELESS M-Bus S, T & C modes. The coverage range can be extended with M-Bus WIRELESS (MBWRPT) repeaters. Integrated SIM CARD with one year of operation. 230V 50Hz power supply.
CONTER R
Product Type | Model |
---|---|
Hydraulic interface unit for re-buildings | Conter R |
COMPONENTS | |
Strainer | |
Inlet manual interception valves | |
2-way body valve | |
Heat exchanger | |
Pump | |
Safety valve | |
Manometer | |
Safety thermostat | |
Expansion vessel | |
Filling point | |
Electronics management box | |
Wireless M-Bus heat meters | |
Sintesi 2-way modulating actuator | |
Flow temperature probe | |
Mechanical energy meter, heating only, M-Bus / Ultrasonic energy meter, heating only, M-Bus / Mechanical energy meter, heating only, wireless M-Bus / Ultrasonic energy meter, heating only, wireless M-Bus | |
Flow rate control with balancing valve | Optional |
Distribution manifold with motorized valves / Distribution manifold with electromechanical heads | Optional |
External probe for wheather compensation | Optional |
System start-up and technical support | Optional |
The hydraulic interface unit for the re-buildings
Studied for the one who wants to replace the radiators with the radiant panels in centralized plants.
Recessed installation.
Complete of the whole material to manage the new plant to panels radiant plates.
Heat exchanger for the complete hydraulic separation.
ERP Ready pump.
Wireless M-Bus direct metering.
Surge chamber.
Safety valve.
Sintesi modulating motorised valve.
Electronics management file with digital display.
Temperature probe and safety thermostat.
Available also with distribution manifolds.
CONTER D
Product Type | Model |
---|---|
Hydraulic interface unit with heating/cooling line, DHW and/or DCW lines and manifold for fluid distribution | Conter D |
COMPONENTS | |
Strainer | |
2-way or by-pass body valve | |
Sintesi 230V actuator * / Sintesi 24V actuator / Sintesi 230V actuator with safety electronics | |
Inlet manual interception valves | |
Included manifold with Microdiam control actuator on the zones / Included manifold with electromechanical heads | |
Electronics management box | |
Metal sheet box | |
Mechanical energy meter, M-Bus / Mechanical energy meter (heating/cooling) M-Bus | |
Energy line insulation | Optional |
Flow rate control with static flow meter / Flow rate control with static balancing valve / Flow rate control with dynamic balancing valve / Flow rate control with ERP pump | Optional |
Thermostatic mixer for domestic water | Optional |
DHW-DCW additional set for water line with stub piece / DHW additional set for 1 water line with stub piece / DCW additional set for 1 water line with stub piece | Optional |
DCW meter with pulse outputs / DHW meter with pulse outputs | Optional |
Door and frame | Optional |
System start-up and technical support | Optional |
* Warning: the 230V motorised valve must be combined with a suitable electrical safety system according to law, such as our optional CGQKHT |
Direct energy metering
Centralised heating plant management
Centralised DHW production
Integrated distribution manifolds
Hot and cold sanitary water lines
Build-into-wall installation
Repeater
Code | Description |
---|---|
MBWRPT | Repeater Wireless |
Unidirectional Wireless M-Bus 868Mhz repeater. Single-hop support. Software-configurable. 230V 50Hz power supply.
LOWTHERM
Product Type | Model |
---|---|
Hydraulic interface unit with heating/cooling line in high and low temperature and DHW and/or DCW lines | Lowtherm |
COMPONENTS | |
Strainer | |
Inlet manual interception valves | |
Outlet manual interception valves | |
2-way or by-pass body valve | |
Sintesi 230V actuator * / Sintesi 24V actuator / Sintesi 230V actuator with safety electronics | |
Additional outlet low temperature heating | |
Mechanical energy meter, M-Bus / Mechanical energy meter (heating/cooling) M-Bus | |
Low temperature circuit pump | |
Sintesi 2-way modulating motorised valve on low temperature circuit | |
Safety thermostat for low temperature circuit | |
Low temperature probe | |
Non-return valve | |
Metal sheet box | |
Template box | |
Mechanical energy meter, direct read out / Mechanical energy meter (heating/cooling) M-Bus ** | |
DHW-DCW additional set for water line with stub piece / DHW additional set for 1 water line with stub piece / DCW additional set for 1 water line with stub piece | Optional |
DCW meter with pulse outputs / DHW meter with pulse outputs | Optional |
Door and frame | Optional |
System start-up and technical support | Optional |
* Warning: the 230V motorised valve must be combined with a suitable electrical safety system according to law, such as our optional CGQKHT |
Direct energy metering
Centralised heating plant management with high and low temperature
Centralised DHW production
Hot and cold sanitary water lines
Double energy outlet (one direct zone and one zone with controlled temperature and pump)
Integrated electonics for heating and cooling control by setting a fixed or varible value through an external sensor
Auto-limititing system of the flow temperatue for the cooling line to avoid condensate presence on the floor (with sensor for relative humidy to be installed in the room)
Build-into-wall installation
Bitherm
Product Type | Model |
---|---|
Hydraulic interface unit for DHW production and complete hydraulic separation on heating circuit with temperature control | Bitherm |
COMPONENTS | |
Strainer | |
DHW temperature probe | |
Flowmeter | |
Flow static limiter | |
Heat exchanger for heating circuit | |
Heat exchanger for sanitary circuit | |
Sintesi 2-way modulating motorised valve on sanitary circuit | |
Sintesi 2-way ON/OFF motorised valve on primary circuit | |
Electronics management box | |
Energy meter, M-Bus reading / Ultrasonic energy meter | |
Sanitary water meter, M-Bus reading | |
Pump | |
Safety valve | |
Expansion vessel | |
Manometer | |
Filling point | |
Cover | |
Inlet manual interception valves | Optional |
Outlet manual interception valves | Optional |
Temperature control on heating circuit | Optional |
Pump for sanitary circuit | Optional |
Plant balancing with static balancing valve / Plant balancing with dynamic balancing valve / Plant balancing with DPCV / Plant balancing with Modflow - electronic flow control | Optional |
System start-up and technical support | Optional |
Direct energy metering
Centralised heating plant management
Hydraulic separation
Two plated heat exchangers for DHW production and heating
Hot and cold sanitary water lines
For heating plant with condensing boiler
DIATECH S
Product Type | Model |
---|---|
Hydraulic interface unit for heating and DHW production | Diatech S |
COMPONENTS | |
Strainer | |
Manual interception valves (version with template box) | |
DHW temperature probe | |
Flowmeter | |
Flow static limiter | |
Heat exchanger | |
Sintesi 2-way modulating motorised valve on sanitary circuit | |
Sintesi 2-way ON/OFF motorised valve on primary circuit | |
Electronics management box | |
Energy meter, M-Bus reading / Ultrasonic energy meter | |
Sanitary water meter, M-Bus reading | |
Treated and/or pre-heated sanitary water meter, M-Bus reading | Optional |
Template box (recessed installation) | Optional |
White casing (wall hanging) | Optional |
Pump on primary circuit | Optional |
Recirculation on primary circuit | Optional |
Plant balancing with static balancing valve / Plant balancing with dynamic balancing valve / Plant balancing with DPCV / Plant balancing with Modflow - electronic flow control | Optional |
Non-return valve | Optional |
System start-up and technical support | Optional |
Direct energy metering
Centralised heating plant management
Plated heat exchanger for DHW production
Hot and cold sanitary water lines
For traditional heating plant
Diatech SR
Product Type | Model |
---|---|
Hydraulic interface unit for heating and cooling systems and DHW production | Diatech SR |
COMPONENTS | |
Strainer | |
Inlet manual interception valves | |
Outlet manual interception valves | |
DHW temperature probe | |
Flowmeter | |
Flow static limiter | |
Heat exchanger | |
Sintesi 2-way modulating motorised valve on sanitary circuit | |
Sintesi 2-way ON/OFF motorised valve on primary circuit | |
Electronics management box | |
Energy meter, M-Bus reading / Ultrasonic energy meter | |
Sanitary water meter, M-Bus reading | |
Energy meter, M-Bus reading for cooling / Ultrasonic energy meter for cooling | |
Sintesi 2-way ON/OFF motorised valve on low temperature heating circuit | |
Cooling line insulation | |
Template box | |
Door and frame | |
Plant balancing with static balancing valve / Plant balancing with dynamic balancing valve / Plant balancing with DPCV / Plant balancing with Modflow - electronic flow control | Optional |
System start-up and technical support | Optional |
Direct energy metering
Centralised heating plant management
Plated heat exchanger for DHW production
Hot and cold sanitary water lines
For traditional heating plant
DIATECH LF
Product Type | Model |
---|---|
Hydraulic interface unit for heating and DHW production with increased heat exchanger for condensation plants | Diatech LF |
COMPONENTS | |
Strainer | |
Manual interception valves (version with template box) | |
DHW temperature probe | |
Flowmeter | |
Flow static limiter | |
Heat exchanger | |
Sintesi 2-way modulating motorised valve on sanitary circuit | |
Sintesi 2-way ON/OFF motorised valve on primary circuit | |
Electronics management box | |
Energy meter, M-Bus reading / Ultrasonic energy meter | |
Sanitary water meter, M-Bus reading | |
Treated and/or pre-heated sanitary water meter, M-Bus reading | Optional |
Template box (recessed installation) | Optional |
White casing (wall hanging) | Optional |
Pump on primary circuit / Recirculation on primary circuit | Optional |
Plant balancing with static balancing valve / Plant balancing with dynamic balancing valve / Plant balancing with DPCV / Plant balancing with Modflow - electronic flow control | Optional |
Non-return valve | Optional |
System start-up and technical support | Optional |
Direct energy metering
Centralised heating plant management
Plated heat exchanger for DHW production
Hot and cold sanitary water lines
For heating plant with condensing boiler
Diatech L
Product Type | Model |
---|---|
Hydraulic interface unit for heating and DHW and DCW production with in-line connection on the inferior side | Diatech L |
COMPONENTS | |
Strainer | |
Inlet manual interception valves | |
Outlet manual interception valves | |
DHW temperature probe | |
Flowmeter | |
Flow static limiter | |
Heat exchanger | |
Sintesi 2-way modulating motorised valve on sanitary circuit | |
Sintesi 2-way ON/OFF motorised valve on primary circuit | |
Electronics management box | |
Energy meter, M-Bus reading / Ultrasonic energy meter | |
Sanitary water meter, M-Bus reading | |
Template box | |
Door and frame | |
Plant balancing with static balancing valve / Plant balancing with dynamic balancing valve / Plant balancing with DPCV / Plant balancing with Modflow - electronic flow control | Optional |
System start-up and technical support | Optional |
Direct energy metering
Centralised heating plant management
Plated heat exchanger for DHW production
Hot and cold sanitary water lines
For traditional heating plant
In-line connection from the bottom