CONTER S
Product Type | Model |
---|---|
Hydraulic interface unit with heating/cooling lines and domestic hot and cold water | Conter S |
COMPONENTS | |
Strainer | |
Manual interception valves | |
Sintesi actuator 230V AC ON/OFF 1 microswitch / Sintesi actuator 24V AC ON/OFF 1 microswitch | |
1 heat meter and 2 DCW and DHW meters, M-Bus / 1 energy meter (heating/cooling) and 2 DCW and DHW meters, M-Bus | |
Frame and door | Optional |
Energy line insulation | Optional |
Flow rate control with balancing valve | Optional |
System start-up and technical support | Optional |
Direct energy metering
Centralised heating plant management
Centralised DHW production
Hot and cold sanitary water lines
Build-into-wall installation
CONTER
Product Type | Model |
---|---|
Configurable hydraulic interface unit with heating/cooling line | Conter |
COMPONENTS | |
Strainer | |
2-way or by-pass body valve | |
Inlet manual interception valves | |
Sintesi 230V actuator * / Sintesi 24V actuator / Sintesi 230V actuator with safety electronics | |
Mechanical energy meter, M-Bus / Mechanical energy meter (heating/cooling) M-Bus | |
Energy line insulation | Optional |
Flow rate control with static flow meter / Flow rate control with static balancing valve / Flow rate control with dynamic balancing valve / Flow rate control with ERP pump | Optional |
Low temperature (LT) plant with Sintesi 230V actuator and electronics | Optional |
Outlet manual interception valves | Optional |
DHW-DCW additional set for water line with stub piece / DHW additional set for 1 water line with stub piece / DCW additional set for 1 water line with stub piece | Optional |
DCW meter with pulse outputs / DHW meter with pulse outputs | Optional |
Small metal sheet box (for basic models) / Big metal sheet box (for models with flow regulation and manual interception valves or LT option) / Square shaped metal sheet box | Optional |
Small door and frame for QSA (for basic models) / Big door and frame for QSB (for models with flow regulation and manual interception valves or LT option) / Square shaped door and frame for QSC | Optional |
System start-up and technical support | Optional |
* Warning: the 230V motorised valve must be combined with a suitable electrical safety system according to law, such as our optional CGQKHT |
Direct energy metering
Centralised heating plant management
Centralised DHW production
Optional hot and cold sanitary water lines
Build-into-wall installation
CONTER R
Product Type | Model |
---|---|
Hydraulic interface unit for re-buildings | Conter R |
COMPONENTS | |
Strainer | |
Inlet manual interception valves | |
2-way body valve | |
Heat exchanger | |
Pump | |
Safety valve | |
Manometer | |
Safety thermostat | |
Expansion vessel | |
Filling point | |
Electronics management box | |
Wireless M-Bus heat meters | |
Sintesi 2-way modulating actuator | |
Flow temperature probe | |
Mechanical energy meter, heating only, M-Bus / Ultrasonic energy meter, heating only, M-Bus / Mechanical energy meter, heating only, wireless M-Bus / Ultrasonic energy meter, heating only, wireless M-Bus | |
Flow rate control with balancing valve | Optional |
Distribution manifold with motorized valves / Distribution manifold with electromechanical heads | Optional |
External probe for wheather compensation | Optional |
System start-up and technical support | Optional |
The hydraulic interface unit for the re-buildings
Studied for the one who wants to replace the radiators with the radiant panels in centralized plants.
Recessed installation.
Complete of the whole material to manage the new plant to panels radiant plates.
Heat exchanger for the complete hydraulic separation.
ERP Ready pump.
Wireless M-Bus direct metering.
Surge chamber.
Safety valve.
Sintesi modulating motorised valve.
Electronics management file with digital display.
Temperature probe and safety thermostat.
Available also with distribution manifolds.
CONTER D
Product Type | Model |
---|---|
Hydraulic interface unit with heating/cooling line, DHW and/or DCW lines and manifold for fluid distribution | Conter D |
COMPONENTS | |
Strainer | |
2-way or by-pass body valve | |
Sintesi 230V actuator * / Sintesi 24V actuator / Sintesi 230V actuator with safety electronics | |
Inlet manual interception valves | |
Included manifold with Microdiam control actuator on the zones / Included manifold with electromechanical heads | |
Electronics management box | |
Metal sheet box | |
Mechanical energy meter, M-Bus / Mechanical energy meter (heating/cooling) M-Bus | |
Energy line insulation | Optional |
Flow rate control with static flow meter / Flow rate control with static balancing valve / Flow rate control with dynamic balancing valve / Flow rate control with ERP pump | Optional |
Thermostatic mixer for domestic water | Optional |
DHW-DCW additional set for water line with stub piece / DHW additional set for 1 water line with stub piece / DCW additional set for 1 water line with stub piece | Optional |
DCW meter with pulse outputs / DHW meter with pulse outputs | Optional |
Door and frame | Optional |
System start-up and technical support | Optional |
* Warning: the 230V motorised valve must be combined with a suitable electrical safety system according to law, such as our optional CGQKHT |
Direct energy metering
Centralised heating plant management
Centralised DHW production
Integrated distribution manifolds
Hot and cold sanitary water lines
Build-into-wall installation
LOWTHERM
Product Type | Model |
---|---|
Hydraulic interface unit with heating/cooling line in high and low temperature and DHW and/or DCW lines | Lowtherm |
COMPONENTS | |
Strainer | |
Inlet manual interception valves | |
Outlet manual interception valves | |
2-way or by-pass body valve | |
Sintesi 230V actuator * / Sintesi 24V actuator / Sintesi 230V actuator with safety electronics | |
Additional outlet low temperature heating | |
Mechanical energy meter, M-Bus / Mechanical energy meter (heating/cooling) M-Bus | |
Low temperature circuit pump | |
Sintesi 2-way modulating motorised valve on low temperature circuit | |
Safety thermostat for low temperature circuit | |
Low temperature probe | |
Non-return valve | |
Metal sheet box | |
Template box | |
Mechanical energy meter, direct read out / Mechanical energy meter (heating/cooling) M-Bus ** | |
DHW-DCW additional set for water line with stub piece / DHW additional set for 1 water line with stub piece / DCW additional set for 1 water line with stub piece | Optional |
DCW meter with pulse outputs / DHW meter with pulse outputs | Optional |
Door and frame | Optional |
System start-up and technical support | Optional |
* Warning: the 230V motorised valve must be combined with a suitable electrical safety system according to law, such as our optional CGQKHT |
Direct energy metering
Centralised heating plant management with high and low temperature
Centralised DHW production
Hot and cold sanitary water lines
Double energy outlet (one direct zone and one zone with controlled temperature and pump)
Integrated electonics for heating and cooling control by setting a fixed or varible value through an external sensor
Auto-limititing system of the flow temperatue for the cooling line to avoid condensate presence on the floor (with sensor for relative humidy to be installed in the room)
Build-into-wall installation