Balancing ball valves – Diamant PICV
Codice / Code | Connessione / Connection | DN | PN | Portata massima / Max flow rate |
---|---|---|---|---|
DPCV40A | 1"1/2 | 40 | 16 | 6.000 l/h |
DPCV40B | 1"1/2 | 40 | 16 | 9.000 l/h |
DPCV50A | 2" | 50 | 16 | 12.000 l/h |
DPCV50B | 2" | 50 | 16 | 18.000 l/h |
PICV: Pressure Indipendent Control Valve
V-ball profile
The PICV combines the differential pressure control function with the features of a regulation valve and a 2-way control valve.

DIAMANT 2000
Codice / Code | Per corpo valvola / For ball valve | V | Frequenza / Frequency | Coppia / Torque | Tempi di manovra / Operating times | Angolo ° / Angle ° |
---|---|---|---|---|---|---|
DY222 | 2 - 3 VIE / WAY | 230V | 50/60 Hz | 11 Nm | 35 sec | 90° |
DY212 | 2 - 3 VIE / WAY | 110V | 50/60 Hz | 11 Nm | 35 sec | 90° |
DY242 | 2 - 3 VIE / WAY | 24V | 50/60 Hz | 11 Nm | 35 sec | 90° |
DY322 | 3 VIE / WAY | 230V | 50/60 Hz | 11 Nm | 70 sec | 180° |
DY312 | 3 VIE / WAY | 110V | 50/60 Hz | 11 Nm | 70 sec | 180° |
DY342 | 3 VIE / WAY | 24V | 50/60 Hz | 11 Nm | 70 sec | 180° |
HEATING / COOLING
ALL-IN-ONE actuator for 3 points without relay or 2 points with relay connection
Class protection: IP65
Operating time: 35 sec for 90° rotation – 11Nm

Diamant Pilot
Creazione codice tramite CODE BUILDER / Code creation via CODE BUILDER | es: DPV24CCATR |
---|---|
Diamant Pilot | DP |
Tipologia di comando/ Control type | |
2-3 punti ON/OFF / 2-3 point ON-OFF | Y |
3 posizioni 0°-45°-90° / 3 positions 0°-45°-90° | T |
3 posizioni 0°-90°-180° / 3 positions 0°-90°-180° | S |
0-20 mA | A |
4-20 mA | B |
0-10 V | V |
2-10 V | W |
PWM1 | P |
PWM2 | Q |
Angolo di rotazione / Rotation angle | |
90° | 2 |
180° | 3 |
Alimentazione elettrica / Power supply | |
100... 240V 50/60Hz | 2 |
24V AC/DC | 4 |
12V DC | 5 |
Connessione al corpo valvola / Connection to the ball valve | |
Comparato | C |
ISO 5211 F03-F05 Q 9-11 | F |
Fail Safe | |
Presente in apertura / When opening | A |
Presente in chiusura / When closing | C |
Presente in posizione intermedia / In the intermediate position | I |
Assente / Not present | O |
Apertura manuale di emergenza / Emergency Manual Opening | |
Presente / Present | A |
Tempo di manovra / Operating time | |
15 sec / 90° | Q |
30 sec / 90° | T |
60 sec / 90° | S |
120 sec / 90° | C |
Resistenza scaldante / Heating resistance | |
Presente / Present | R |
Assente / Not present | O |
USE: INDUSTRIAL PLANTS, AUTOMATION SYSTEMS, HEATING / COOLING AND SANITARY WATER
TORQUE: 11 Nm
POSITIONING FEEDBACK 2-10V
TWO EXTRA MICRO SWITCHES
INGRESS PROTECTION: IP67
MANUAL OPENING

Diamant Smart PRO
Creazione codice tramite CODE BUILDER / Code creation via CODE BUILDER | es: DSP24CWFA |
---|---|
Diamant Smart PRO | DSP |
Angolo di rotazione / Rotation angle | |
90° | 2 |
180° | 3 |
Alimentazione elettrica / Power supply | |
100... 240V 50/60Hz | 2 |
12-24V AC/DC | 4 |
Connessione al corpo valvola / Connection to the ball valve | |
Comparato | C |
ISO 5211 F03-F05 Q 9-11 | F |
Tipo di comunicazione / Communication type | |
Modbus | M |
Wi-Fi | W |
Fail Safe | |
Presente / Present | F |
Assente / Not present | O |
Apertura manuale di emergenza / Emergency Manual Opening | |
Presente / Present | A |
USE: INDUSTRIAL PLANTS, AUTOMATION SYSTEMS, HEATING / COOLING AND SANITARY WATER
TORQUE: 11 Nm
POSITIONING FEEDBACK 2-10V
TWO EXTRA MICRO SWITCHES
COMMUNICATION VIA WI-FI OR MODBUS-RTU
INGRESS PROTECTION: IP67
MANUAL OPENING