DIAMIX L motorised valve – FFF vertical mixed outlet
| Codice / Code | Tensione / P. supply | Connessione / Connection | DN | KVs | PN | ΔP |
|---|---|---|---|---|---|---|
| DIAMIXPFAL | 230 V 50/60 Hz | 1/2" | 15 | 6 | 25 | 25 bar |
| DIAMIXPFBL | 230 V 50/60 Hz | 3/4" | 20 | 11,5 | 16 | 16 bar |
| DIAMIXPFCL | 230 V 50/60 Hz | 1" | 25 | 18,3 | 16 | 16 bar |
For DOMESTIC HOT WATER with integrated system for LEGIONELLA bacteria disinfection
Mixing thermoregulating actuator with electronics onboard
Semiconductor temperature sensor
Class protection IP65
3-way BRASS ball valve, FFF vertical/horizontal, full bore
Remote management with Modbus-RTU protocol
SINTESI SMART MODBUS – proportional control
| Codice / Code | Alimentazione / Electrical supply | Protocollo di comunicazione / Communication protocol | Coppia / Torque |
|---|---|---|---|
| SMmodbus | 24V AC/DC | Modbus | 8 Nm |
New Comparato actuator with proportional control in tension or in current for modern heating and cooling plants.
Thanks to its peculiarities, it meets need of precise, reliable and long lasting regulation and, thanks to its “smart” heart, it can be used in all applications needing a flow mixing or partialization.
SINTESI SMART IS M-BUS CONTROLLED IN NEW GENERATION DOMOTIC SYSTEMS.
RIGHT MIXING – DN25
| Code | Type |
|---|---|
| GR1X0D | elettronico per riscaldamento electronic for heating |
| GR2X0D | elettronico per riscaldamento - alta portata electronic for heating - high flow |
| GR1XFD | elettronico per raffrescamento electronic for cooling |
| GR2XFD | elettronico per raffrescamento- alta portata electronic for cooling - high flow |
1″ connections
Span 125mm
Power supply: 230V 50/60Hz
Outlet on the right side and return on the left side
Insulation included
ECOSAN PDC
| Creazione codice tramite CODE BUILDER / Code creation via CODE BUILDER | es: ECOPC350R0 |
|---|---|
| Produzione istantanea ACS per pompa di calore/ DHW instantaneous production for heat pumps | |
| Radice codice/ Code reference | ECOPC |
| Potenza nominale/ Nominal power | |
| 35 kW | 35 |
| 50 kW | 50 |
| Controllo temepratura mandata primario/ Primary flow temperature control | |
| Non presente/ not present | O |
| valvola miscelatrice 3 vie/ 3-way mixing valve | 1 |
| Funzioni accessorie/ Extra functions | |
| Non presente/ not present | O |
| linea ricircolo ACS con antilegionella/ DHW recirculation with cycle against legionella | R |
| Valvola 3 vie per stratificazione accumulo inerziale/ 3-way valve for water stratification | D |
| Attivazione del generatore con sonda ad immersione per accumulo inerziale/ Generator activation through immersion temperature probe for puffer | 3 |
| Predisposizione contatore di calore/ Heat meter ready | |
| Non presente/ not present | O |
| Tronchetto sostitutivo 3/4"x110mm/ Stub piece 3/4"x110mm | T |
Hydraulic interface unit for domestic hot water instantaneous production with heat plate exchanger for plants with heat pump:
• Puffer temperature ≤ 50°C
• Nominal power 35 kW or 50 kW
• Electronic regulation with PWM modulation of the pump
• Compact wall mounting
• Remote management with Modbus-RTU protocol
DIAMANT PRO actuator
| Codice / Code | Per corpo valvola / For ball valve | V | Frequenza / Frequency | Coppia / Torque | Tempi di manovra / Operating times | Angolo ° / Angle ° |
|---|---|---|---|---|---|---|
| DY222P2 | 2 - 3 VIE / WAY | 230V | 50/60 Hz | 11 Nm | 35 sec | 90° |
| DY212P2 | 2 - 3 VIE / WAY | 110V | 50/60 Hz | 11 Nm | 35 sec | 90° |
| DY242P2 | 2 - 3 VIE / WAY | 24V | 50/60 Hz | 11 Nm | 35 sec | 90° |
| DY322P2 | 3 VIE / WAY | 230V | 50/60 Hz | 11 Nm | 70 sec | 180° |
| DY312P2 | 3 VIE / WAY | 110V | 50/60 Hz | 11 Nm | 70 sec | 180° |
| DY342P2 | 3 VIE / WAY | 24V | 50/60 Hz | 11 Nm | 70 sec | 180° |
HEATING / COOLING / INDUSTRIAL USE
ALL-IN-ONE actuator for 3 points without relay or 2 points with relay connection
Class protection: IP67
Operating time: 35 sec for 90° rotation – 11Nm
ECOSAN PDC L
| Codice / Code | Descrizione/ Description |
|---|---|
| ECOSL100 | potenza nominale produzione istantanea ACS 100 kW/ 100 kW DHW instantaneous production nominal power |
| ECOSL150 | potenza nominale produzione istantanea ACS 150 kW/ 150 kW DHW instantaneous production nominal power |
Hydraulic interface unit for domestic hot water instantaneous production with heat plate exchanger for plants with heat pump:
• Puffer temperature ≤ 50°C
• Nominal power 100 kW or 150 kW
• Electronic mixer for DHW temperature control
• Domestic recirculation line with programmable
anti-legionella thermal disinfection
• Recirculation return temperature control
with PWM modulation of the pump
• Bedplate installation
• Comparato’s LegioTool software for communication
between PC and mixing valve with data downloading
• Remote management with Modbus-RTU protocol
Futura Ac
| Product Type | Model |
|---|---|
| Hydraulic interface unit for heating system with accumulation tank for DHW production 50 L or 70 L | Futura AC |
| COMPONENTS | |
| Strainer | |
| Flowswitch for sanitary priority | |
| Flow static limiter | |
| Accumulation tank | |
| Manual relief valve | |
| 7 bar safety valve | |
| AISI 304 expansion vessel | |
| AISI 316L immersion temperature probe | |
| Automatic release valve | |
| Sintesi 2-way ON/OFF motorised valve on sanitary circuit | |
| Sintesi 2-way ON/OFF motorised valve on primary circuit | |
| Non-return valve | |
| Electronics management box | |
| Probe holder for energy meter | |
| 1500 W electric heater for DHW boiler | Optional |
| Energy meter, M-Bus reading | Optional |
| Sanitary water meter, M-Bus reading | Optional |
| Thermostatic mixer on DHW outlet | Optional |
| Plant pump | Optional |
| Additional outlet low temperature heating | Optional |
| Sintesi 2-way modulating motorised valve on low temperature circuit | Optional |
| Low temperature circuit pump | Optional |
| Low temperature probe | Optional |
| Safety thermostat for low temperature circuit | Optional |
| Outdoor temperature probe for climatic function | Optional |
| System start-up and technical support | Optional |
Direct energy metering
Centralised heating plant management
Accumulation tank for DHW production
Hot and cold sanitary water lines
For traditional heating plant